20-488kVA: DCEC Cummins Series
DCEC Cummins Series: Driven by Joint-venture Cummins Engines
- Capable, reliable and high quality power units
- Fully load tested and checked under standard procedures
- Options for further specifications to tailor make specific power needs
4B3.9 Series (20-100kVA)
Engine Models:
4B3.9-G11 | 4BT3.9-G2 | 4BT3.9-G12 | 4BT3.9-G2 | 4BTA3.9-G2 | 4BTA3.9-G11
4B3.9-G11 | 4BT3.9-G2 | 4BT3.9-G12 | 4BT3.9-G2 | 4BTA3.9-G2 | 4BTA3.9-G11

Prime Rating (kVA)
20 to 90
Prime Rating (kW)
17 to 72
Standby Rating (kVA)
24 to 100
Standby Rating (kW)
19 to 80
Alternator
Stamford
6B5.9 Series (94-175kVA)
Engine Models:
6BT5.9-G2 | 6BTA5.9-G2 |
6BTAA5.9-G2 | 6BTAA5.9-G12
6BT5.9-G2 | 6BTA5.9-G2 |
6BTAA5.9-G2 | 6BTAA5.9-G12


Prime Rating (kVA)
94 to 160
Prime Rating (kW)
75 to 128
Standby Rating (kVA)
103 to 175
Standby Rating (kW)
82 to 140
Alternator
Stamford
6CT8.3 Series (180-230kVA)
Engine Models:
6CTA8.3-G2 | 6CTAA8.3-G2
6CTA8.3-G2 | 6CTAA8.3-G2


Prime Rating (kVA)
180 to 210
Prime Rating (kW)
145 to 168
Standby Rating (kVA)
200 to 230
Standby Rating (kW)
160 to 184
Alternator
Stamford
6LT Series (250-315kVA)
Engine Models:
6LTAA8.9-G2 | 6LTAA8.9-G3 |
6LTAA9.5-G1 | 6LTAA9.5-3
6LTAA8.9-G2 | 6LTAA8.9-G3 |
6LTAA9.5-G1 | 6LTAA9.5-3


Prime Rating (kVA)
250 to 285
Prime Rating (kW)
200 to 228
Standby Rating (kVA)
264 to 315
Standby Rating (kW)
211 to 252
Alternator
Stamford
6ZT Series (388-475kVA)
Engine Models:
6ZTAA13-G3 | 6ZTAA13-G2
6ZTAA13-G3 | 6ZTAA13-G2


Prime Rating (kVA)
388 to 438
Prime Rating (kW)
310 to 350
Standby Rating (kVA)
425 to 475
Standby Rating (kW)
340 to 380
Alternator
Stamford
QSB Series (60-200kVA)
Engine Models:
QSB3.9-G2 | QSB3.9-G3 | QSB5.9-G2 | QSB5.9-G3 | QSB6.7-G3 | QSB6.7-G4
QSB3.9-G2 | QSB3.9-G3 | QSB5.9-G2 | QSB5.9-G3 | QSB6.7-G3 | QSB6.7-G4


Prime Rating (kVA)
60 to 180
Prime Rating (kW)
48 to 144
Standby Rating (kVA)
70 to 200
Standby Rating (kW)
56 to 160
Alternator
Stamford
QSL Series (200-275kVA)
Engine Models:
QSL8.9-G2 | QSL8.9-G3 | QSL8.9-G4
QSL8.9-G2 | QSL8.9-G3 | QSL8.9-G4


Prime Rating (kVA)
200 to 250
Prime Rating (kW)
160 to 200
Standby Rating (kVA)
220 to 275
Standby Rating (kW)
176 to 220
Alternator
Stamford
QSZ Series (438-488kVA)
Engine Models:
QSZ13-G2 | QSZ13-G3 | QSZ13-G5 |
QSZ13-G6 | QSZ13-G7
QSZ13-G2 | QSZ13-G3 | QSZ13-G5 |
QSZ13-G6 | QSZ13-G7


Prime Rating (kVA)
438 to 450
Prime Rating (kW)
350 to 360
Standby Rating (kVA)
468 to 488
Standby Rating (kW)
375 to 390
Alternator
Stamford
*The technical data provided is subject to change without notice.